{"id":15256,"date":"2026-10-06T14:31:55","date_gmt":"2026-10-06T12:31:55","guid":{"rendered":"https:\/\/www.entecerma.it\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/"},"modified":"2026-10-06T14:41:09","modified_gmt":"2026-10-06T12:41:09","slug":"lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment","status":"publish","type":"post","link":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/","title":{"rendered":"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Lawn mowers intended for the European market must comply with strict technical and regulatory requirements to be marketed and used safely. Ensuring the compliance of these machines is not only a legal obligation, but a fundamental requirement to protect operator health and safety, as well as to safeguard the environment and other electronic devices.<\/p>\n\n<p class=\"wp-block-paragraph\">To obtain the CE marking, manufacturers and importers must subject lawn mowers to specific assessment procedures covering three main areas: electromagnetic compatibility (EMC), noise emissions, and vibration levels.<\/p>\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-d05cb3ef wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"1200\" src=\"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-65.png\" alt=\"\" class=\"wp-image-15134\" srcset=\"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-65.png 1200w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-65-150x150.png 150w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-65-768x768.png 768w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-65-1024x1024.png 1024w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-65-500x500.png 500w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n<\/div>\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading has-vivid-cyan-blue-color has-text-color has-link-color wp-elements-1\"><strong>ELECTROMAGNETIC COMPATIBILITY (EMC) TESTING<\/strong><\/h3>\n\n<p class=\"wp-block-paragraph\"><div id=\"model-response-message-contentr_d20d830742bc6636\" class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"polite\">&#13;\n<div>Modern lawn mowers\u2014whether battery-powered, corded, or robotic\u2014integrate sophisticated electronic components and control systems. Electromagnetic Compatibility (EMC) testing is essential to ensure that the equipment does not generate interference capable of affecting other devices and, at the same time, is immune to external interference.<\/div><br\/><\/div><\/p>\n\n<p class=\"wp-block-paragraph\"><div id=\"model-response-message-contentr_e318cc280f029cea\" class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"polite\">&#13;\n<div>Ente Certificazione Macchine is a Testing Laboratory (No. 121697) accredited by PJLA in accordance with ISO\/IEC 17025. At our laboratory, specialized technicians perform precise measurements to ensure that every component operates stably, avoiding electronic malfunctions that could compromise user safety during mowing operations.<\/div><br\/><\/div><\/p>\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-d05cb3ef wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"1200\" src=\"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-66.png\" alt=\"\" class=\"wp-image-15137\" srcset=\"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-66.png 1200w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-66-150x150.png 150w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-66-768x768.png 768w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-66-1024x1024.png 1024w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-66-500x500.png 500w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n<\/div>\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading has-vivid-cyan-blue-color has-text-color has-link-color wp-elements-2\"><strong>NOISE DIRECTIVE (2000\/14\/EC): ENVIRONMENTAL NOISE AND ACOUSTIC IMPACT<\/strong><\/h3>\n\n<p class=\"wp-block-paragraph\"><div id=\"model-response-message-contentr_a7f3900b99a27285\" class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"polite\">&#13;\n<div>For lawn mowers, noise emission control is a stringent legal requirement under Directive 2000\/14\/EC on equipment for use outdoors. ECM performs rigorous testing to determine the guaranteed sound power level, carrying out outdoor measurements in compliance with international standards.<\/div><br\/><\/div><\/p>\n\n<p class=\"wp-block-paragraph\"><div id=\"model-response-message-contentr_9697c063d61a4a2a\" class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"polite\">&#13;\n<div><b data-path-to-node=\"0\" data-index-in-node=\"0\">Why is it important?<\/b> These tests allow manufacturers to certify the noise levels declared on the label and in the user manual. A proper assessment not only ensures regulatory compliance, but also reduces environmental noise impact and improves acoustic comfort for operators and the community.<\/div><br\/><\/div><\/p>\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-d05cb3ef wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"1200\" src=\"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-67.png\" alt=\"\" class=\"wp-image-15142\" srcset=\"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-67.png 1200w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-67-150x150.png 150w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-67-768x768.png 768w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-67-1024x1024.png 1024w, https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-67-500x500.png 500w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n<\/div>\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading has-vivid-cyan-blue-color has-text-color has-link-color wp-elements-3\"><strong>VIBRATION RISK ASSESSMENT AND MITIGATION<\/strong><\/h3>\n\n<p class=\"wp-block-paragraph\"><div id=\"model-response-message-contentr_5e7a45d39610909b\" class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"polite\">&#13;\n<div>In addition to noise and electromagnetic impact, evaluating operator exposure to vibration represents a crucial element for the overall safety of the machine. ECM conducts specific vibration tests in accordance with standard UNI EN ISO 5395-1:2018 for garden equipment and lawn mowers.<\/div><br\/><\/div><\/p>\n\n<p class=\"wp-block-paragraph\">Measurements are conducted by positioning accelerometric sensors on operator contact points (such as the handlebar, controls, or seat) to determine the weighted acceleration transmitted to the hand-arm system or whole body. Compliance with regulatory limits ensures ergonomic use, reducing user health risks associated with prolonged operation and enabling the inclusion of precise, reliable data in the user manual.<\/p>\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading has-vivid-cyan-blue-color has-text-color has-link-color wp-elements-4\"><strong>ECM: YOUR PARTNER FOR CE MARKING<\/strong><\/h3>\n\n<p class=\"wp-block-paragraph\">Ente Certificazione Macchine offers a complete testing and conformity assessment service. From electromagnetic compatibility testing to outdoor noise emission measurement, every stage of the certification process is managed with the utmost professionalism.<\/p>\n\n<p class=\"wp-block-paragraph\">Thanks to our technical support, companies can place safe, competitive lawn mowers on the market that fully comply with current legal requirements, ensuring reliability and quality for their end customers.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lawn mowers intended for the European market must comply with strict technical and regulatory requirements&#8230;<\/p>\n","protected":false},"author":2,"featured_media":15130,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[12,2],"tags":[],"class_list":["post-15256","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case-history-en","category-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment - Ente Certificazione Macchine<\/title>\n<meta name=\"description\" content=\"Ensuring the compliance of these machines is not only a legal requirement, but also a crucial element in protecting operator safety and health, as well as safeguarding the environment and other electronic devices.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment - Ente Certificazione Macchine\" \/>\n<meta property=\"og:description\" content=\"Ensuring the compliance of these machines is not only a legal requirement, but also a crucial element in protecting operator safety and health, as well as safeguarding the environment and other electronic devices.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/\" \/>\n<meta property=\"og:site_name\" content=\"Ente Certificazione Macchine\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-06T12:31:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-06T12:41:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-64-1024x1024.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"entecerma\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"entecerma\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/\"},\"author\":{\"name\":\"entecerma\",\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/#\\\/schema\\\/person\\\/b2c76707e5a5c46c1c3cf1e617980f5e\"},\"headline\":\"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment\",\"datePublished\":\"2026-10-06T12:31:55+00:00\",\"dateModified\":\"2026-10-06T12:41:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/\"},\"wordCount\":450,\"image\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.entecerma.it\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Change_Li-64.png\",\"articleSection\":[\"Case History\",\"News\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/\",\"url\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/\",\"name\":\"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment - Ente Certificazione Macchine\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.entecerma.it\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Change_Li-64.png\",\"datePublished\":\"2026-10-06T12:31:55+00:00\",\"dateModified\":\"2026-10-06T12:41:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/#\\\/schema\\\/person\\\/b2c76707e5a5c46c1c3cf1e617980f5e\"},\"description\":\"Ensuring the compliance of these machines is not only a legal requirement, but also a crucial element in protecting operator safety and health, as well as safeguarding the environment and other electronic devices.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.entecerma.it\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Change_Li-64.png\",\"contentUrl\":\"https:\\\/\\\/www.entecerma.it\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Change_Li-64.png\",\"width\":1200,\"height\":1200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/\",\"name\":\"Ente Certificazione Macchine\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.entecerma.it\\\/en\\\/#\\\/schema\\\/person\\\/b2c76707e5a5c46c1c3cf1e617980f5e\",\"name\":\"entecerma\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/99fcbedcaa1f19ae59344cedcf7d01cdc9db104925424ad87bc5a34b478ec6c8?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/99fcbedcaa1f19ae59344cedcf7d01cdc9db104925424ad87bc5a34b478ec6c8?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/99fcbedcaa1f19ae59344cedcf7d01cdc9db104925424ad87bc5a34b478ec6c8?s=96&d=mm&r=g\",\"caption\":\"entecerma\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment - Ente Certificazione Macchine","description":"Ensuring the compliance of these machines is not only a legal requirement, but also a crucial element in protecting operator safety and health, as well as safeguarding the environment and other electronic devices.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/","og_locale":"en_US","og_type":"article","og_title":"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment - Ente Certificazione Macchine","og_description":"Ensuring the compliance of these machines is not only a legal requirement, but also a crucial element in protecting operator safety and health, as well as safeguarding the environment and other electronic devices.","og_url":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/","og_site_name":"Ente Certificazione Macchine","article_published_time":"2026-10-06T12:31:55+00:00","article_modified_time":"2026-10-06T12:41:09+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-64-1024x1024.png","type":"image\/png"}],"author":"entecerma","twitter_card":"summary_large_image","twitter_misc":{"Written by":"entecerma","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/#article","isPartOf":{"@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/"},"author":{"name":"entecerma","@id":"https:\/\/www.entecerma.it\/en\/#\/schema\/person\/b2c76707e5a5c46c1c3cf1e617980f5e"},"headline":"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment","datePublished":"2026-10-06T12:31:55+00:00","dateModified":"2026-10-06T12:41:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/"},"wordCount":450,"image":{"@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/#primaryimage"},"thumbnailUrl":"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-64.png","articleSection":["Case History","News"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/","url":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/","name":"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment - Ente Certificazione Macchine","isPartOf":{"@id":"https:\/\/www.entecerma.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/#primaryimage"},"image":{"@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/#primaryimage"},"thumbnailUrl":"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-64.png","datePublished":"2026-10-06T12:31:55+00:00","dateModified":"2026-10-06T12:41:09+00:00","author":{"@id":"https:\/\/www.entecerma.it\/en\/#\/schema\/person\/b2c76707e5a5c46c1c3cf1e617980f5e"},"description":"Ensuring the compliance of these machines is not only a legal requirement, but also a crucial element in protecting operator safety and health, as well as safeguarding the environment and other electronic devices.","breadcrumb":{"@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/#primaryimage","url":"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-64.png","contentUrl":"https:\/\/www.entecerma.it\/wp-content\/uploads\/2026\/09\/Change_Li-64.png","width":1200,"height":1200},{"@type":"BreadcrumbList","@id":"https:\/\/www.entecerma.it\/en\/lawn-mower-certification-and-compliance-emc-testing-noise-emissions-and-vibration-assessment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.entecerma.it\/en\/"},{"@type":"ListItem","position":2,"name":"Lawn Mower Certification and Compliance: EMC Testing, Noise Emissions, and Vibration Assessment"}]},{"@type":"WebSite","@id":"https:\/\/www.entecerma.it\/en\/#website","url":"https:\/\/www.entecerma.it\/en\/","name":"Ente Certificazione Macchine","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.entecerma.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.entecerma.it\/en\/#\/schema\/person\/b2c76707e5a5c46c1c3cf1e617980f5e","name":"entecerma","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/99fcbedcaa1f19ae59344cedcf7d01cdc9db104925424ad87bc5a34b478ec6c8?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/99fcbedcaa1f19ae59344cedcf7d01cdc9db104925424ad87bc5a34b478ec6c8?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/99fcbedcaa1f19ae59344cedcf7d01cdc9db104925424ad87bc5a34b478ec6c8?s=96&d=mm&r=g","caption":"entecerma"}}]}},"_links":{"self":[{"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/posts\/15256","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/comments?post=15256"}],"version-history":[{"count":1,"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/posts\/15256\/revisions"}],"predecessor-version":[{"id":15257,"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/posts\/15256\/revisions\/15257"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/media\/15130"}],"wp:attachment":[{"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/media?parent=15256"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/categories?post=15256"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.entecerma.it\/en\/wp-json\/wp\/v2\/tags?post=15256"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}